Installation Information
Rigid Galvanized Conduit
A minimum 36” trench is typical for most wireless construction with a 6” horizontal spacing between multiple conduits. A 6” caution tape is usually required approximately 1’ below grade level. Minimum NEC burial depth requirements must be observed, but the local utility has the final say. Prior to excavating it is recommended that you contact the local service provider and ensure that you’re aware of their requirements.
Also, contact the telephone company and utility company to see if telco can be buried in the same excavation. Sometimes you’ll be required to provide separate trenches.
The default installation pricing below (under 100') is the cost that a subcontractor will charge to connect and place the rigid conduit in an opened trench while on site. Pricing is adjusted for longer runs. It does not include pulling conductors or any material.
Installation Pricing, Schedule 40 Rigid Metal Galvanized Conduit
|
Nom Pipe Size (in) |
Outside Dia. (in) |
Outside Dia. (mm) |
Inside Dia. (in) |
Inside Dia. (mm) |
Wall Thick-ness (in) |
Weight (lbs) |
Conduit install (ft) |
1/2 |
0.84 |
21.34 |
0.62 |
15.8 |
0.104 |
8.2 |
$0.55
|
3/4
|
1.05
|
26.67
|
0.82
|
20.93
|
0.107
|
10.9
|
$0.60
|
1
|
1.32
|
33.4
|
1.05
|
26.64
|
0.126
|
16.1
|
$0.65
|
1-1/4
|
1.66
|
42.16
|
1.38
|
35.05
|
0.133
|
21.8
|
$0.70
|
1-1/2
|
1.9
|
48.26
|
1.61
|
40.89
|
0.138
|
26.3
|
$0.75
|
2
|
2.38
|
60.33
|
2.07
|
52.5
|
0.146
|
35
|
$0.80
|
2-1/2
|
2.88
|
73.03
|
2.47
|
62.71
|
0.193
|
55.9
|
$0.85
|
3
|
3.5
|
88.9
|
3.07
|
77.93
|
0.205
|
72.7
|
$0.90
|
3-1/2
|
4
|
101.6
|
3.55
|
90.12
|
0.215
|
88
|
$1.00
|
4
|
4.5
|
114.3
|
4.03
|
102.26
|
0.225
|
103
|
$1.20
|
|
|
|
|
|
|
|
|
We recommend that you contact our valued electrical contractors to obtain additional information about their services, capabilities and experience.
|